You are here: Home > Water Heater Replacement Parts > Bradford White > BWCV > BWCV 0500
Bradford White BWCV Volume Water Heaters 0500
Sort By:
Page of 3
Teledyne Laars RA2001700 B&G Pump 1/3 h.p. 3-1/4, A0047100, A0068000, A2001700 Laars R10364504 Header Cover, Inlet/Outlet, Glass-Lined Cast Iron, Previous Part #10364504 Teledyne Laars RA0001200 125 PSI Pressure Relief Valve, 3/4" x 3/4", Previous Part #A0001200
Teledyne Laars RA2001700 B&G Pump 1/3 h.p. 3-1/4, A0047100, A0068000, A2001700 Laars R10364504 Header Cover, Inlet/Outlet, Glass-Lined Cast Iron, Previous Part #10364504 Teledyne Laars RA0001200 125 PSI Pressure Relief Valve, 3/4" x 3/4", Previous Part #A0001200
LAARS S0024600 Gasket LAARS L2013000 Natural Gas Orifice LAARS L2012900 Burner Tray Manifold, 3 Burners, Right, 500-750, 1250-1750
LAARS S0024600 Gasket LAARS L2013000 Natural Gas Orifice LAARS L2012900 Burner Tray Manifold, 3 Burners, Right, 500-750, 1250-1750
LAARS L2012800 Burner Tray Manifold, 3 Burners, Left, 500-750, 1250-1750 LAARS S2012700 Burner Tray Gasket, 3 Burners LAARS 5C5300 Blower Mount Weldment
LAARS L2012800 Burner Tray Manifold, 3 Burners, Left, 500-750, 1250-1750 LAARS S2012700 Burner Tray Gasket, 3 Burners LAARS 5C5300 Blower Mount Weldment
Teledyne Laars RE0240900 Pressure Switch S.P./D.T. LAARS S0095100 Header Gasket LAARS 10338400 Pump Inlet Diffuser Baffle
Teledyne Laars RE0240900 Pressure Switch S.P./D.T. LAARS S0095100 Header Gasket LAARS 10338400 Pump Inlet Diffuser Baffle
Teledyne Laars L2012200 Burner Assembly, 3 Burners, 500, 750, 1250, 1500, 1750 LAARS R2014800 Universal Temperature Control Sensor Kit, E2103300 LAARS 5C3100 Collar, Vent Plate, 6", 500
Teledyne Laars L2012200 Burner Assembly, 3 Burners, 500, 750, 1250, 1500, 1750 LAARS R2014800 Universal Temperature Control Sensor Kit LAARS 5C3100 Collar, Vent Plate, 6", 500
LAARS 5C3004 Cover, Solid, Vent Plate, 500 LAARS 5C3304 Plate, Gas Pipe Seal, 500 TELEDYNE LAARS 20150302 Adapter Tee, Flange, 2" NPT (bronze, outlet side), 500-850
LAARS 5C3004 Cover, Solid, Vent Plate, 500 LAARS 5C3304 Plate, Gas Pipe Seal, 500 TELEDYNE LAARS 20150302 Adapter Tee, Flange, 2" NPT (bronze, outlet side), 500-850
Teledyne Laars A2000700 B&G Pump 1/3 h.p. 3-1/4, A0047100, A0068000, A2001700 Teledyne Laars V2017600 Gas Valve, Direct Ignition
Teledyne Laars A2000700 B&G Pump 1/3 h.p. 3-1/4, A0047100, A0068000, A2001700 Teledyne Laars V2017600 Gas Valve, Direct Ignition, Combination, Dual Automatic Teledyne Laars F0011400 Header Bolt Washer
Honeywell L4008E1313 Manual Reset High-Limit Switch 210F Max LAARS 2400-286 Ignitor, Hot Surface, w/Gasket Teledyne Laars P4hA211900 Wiring Harness, Pennant Blower
Honeywell L4008E1313 Manual Reset High-Limit Switch 210F Max Laars 10-330 Ignitor, Hot Surface, w/Gasket Teledyne Laars P4hA211900 Wiring Harness, Pennant Blower
Teledyne Laars E2313900 Automatic Electronic Ignition Control, 3 Tries, Natural Gas Teledyne Laars A2111900 Pennant Blower, Previous Part #A2108900 LAARS 10483300 Pump Housing, Bronze
Teledyne Laars E2313900 Automatic Electronic Ignition Control, 3 Tries, Natural Gas

Teledyne Laars A2111900 Pennant Blower, Previous Part #A2108900

LAARS 10483300 Pump Housing, Bronze
LAARS 10364201 Pump Adapter, Bronze LAARS 2400-286 Ignitor, Hot Surface, w/Gasket Teledyne Laars 5C3017 Bracket Support, Pump Cover, Previous Part #20C3017
LAARS 10364201 Pump Adapter, Bronze LAARS 2400-286 Ignitor, Hot Surface, w/Gasket Teledyne Laars 5C3017 Bracket Support, Pump Cover, Previous Part #20C3017
Laars 5C3015 Housing, Rain Shield, Pump, Pennant Laars 5C3016 Cover, Housing, Pump, Pennant Laars 10261501 Pump Housing, Glass Lined Cast Lined
Laars 5C3015 Housing, Rain Shield, Pump Laars 5C3016 Cover, Housing, Pump Laars 10261501 Pump Housing, Glass Lined Cast Lined
Teledyne Laars 5C4000 Tube Assembly, Copper, Heat Exchanger, 500 Teledyne Laars R20607600 Pump housing Kit, Mighty Therm 500-1825, Pennant 500-2000 Teledyne Laars R2014901 Tube Assembly, Copper, Heat Exchanger, 500
Teledyne Laars 5C4000 Tube Assembly, Copper, Heat Exchanger, 500 Teledyne Laars R20607600 Pump housing Kit, Mighty Therm 500-1825, Pennant 500-2000 Teledyne Laars R2014901 Tube Assembly, Copper, Heat Exchanger, 500
Teledyne Laars 10-332 Ignitor Gasket, CB/HWG LAARS E2217700 Automatic Reset High-Limit Switch, 210F Max., PNCV LAARS E2217800 Manual Reset High-Limit Switch 210F Max., Pennant, Rheos, Mighty Therm, Mighty Max
Laars 10-332 Ignitor Gasket, CB/HWG

The igniter is a “glow bar” type silicon carbide unit. It is
energized whenever there is a call for heat and the red
"IGNITER" light on the boiler control is lit. After the igniter is
switched off and the boiler continues to run, the igniter functions
as a flame sensor for the boiler control.
If the ignitor fails and must be replaced, always install a new
igniter gasket with the replacement igniter.
CAUTION: Ignitor gets hot.
LAARS E2217700 Automatic Reset High-Limit Switch, 210F Max., PNCV

LAARS E2217800 Manual Reset High-Limit Switch 210F Max.

LAARS E2106900 2-Stage Temperature Control, 500/750 LAARS E2105500 Diagnostic Board LAARS E2105600 Indicator Light Board Panel
LAARS E2106900 2-Stage Temperature Control, 500/750 LAARS E2105500 Diagnostic Board LAARS E2105600 Indicator Light Board Panel
LAARS A0079000 Temperature/Pressure Gauge Teledyne Laars RE0013000 Flow Switch, Previous Part #s:  E0013000, E0013100, RE0013100 LAARS V2000200 Manual Shut-Off Valve
LAARS A0079000 Temperature/Pressure Gauge Teledyne Laars RE0013000 Flow Switch, Previous Part #s:  E0013000, E0013100, RE0013100 LAARS V2000200 Manual Shut-Off Valve