Laars R10364504 Header Cover, Inlet/Outlet, Glass-Lined Cast Iron, Previous Part #10364504 LAARS L2013000 Natural Gas Orifice LAARS L2012700 Burner Tray Manifold, 1000/2000, 4 Burners, Right
Laars R10364504 Header Cover, Inlet/Outlet, Glass-Lined Cast Iron, Previous Part #10364504 LAARS L2013000 Natural Gas Orifice LAARS L2012700 Burner Tray Manifold, 1000/2000, 4 Burners, Right
LAARS L2012600 Burner Tray Manifold, 1000/2000, 4 Burners, Left LAARS S2012500 Burner Tray Gasket, 4 Burners LAARS 5C5300 Blower Mount Weldment
LAARS L2012600 Burner Tray Manifold, 1000/2000, 4 Burners, Left LAARS S2012500 Burner Tray Gasket, 4 Burners LAARS 5C5300 Blower Mount Weldment
Teledyne Laars RE0240900 Pressure Switch S.P./D.T. LAARS 10338400 Pump Inlet Diffuser Baffle LAARS A2109700 Pump 1 hp 2000
Teledyne Laars RE0240900 Pressure Switch S.P./D.T. LAARS 10338400 Pump Inlet Diffuser Baffle LAARS A2109700 Pump 1 hp 2000
Teledyne Laars L2012500 Burner Assembly, 4 Burners, 1000, 1500-2000 LAARS R2014800 Universal Temperature Control Sensor Kit, E2103300 TELEDYNE LAARS 20150302 Adapter Tee, Flange, 2" NPT (bronze, outlet side), 500-850
Teledyne Laars L2012500 Burner Assembly, 4 Burners, 1000, 1500-2000 LAARS R2014800 Universal Temperature Control Sensor Kit TELEDYNE LAARS 20150302 Adapter Tee, Flange, 2" NPT (bronze, outlet side), 500-850
Teledyne Laars V2017600 Gas Valve, Direct Ignition Teledyne Laars RE2317300 Temperature Control with display, FX05
TELEDYNE LAARS R2006600 Sensor, Temperature, Johnson Control, (previous part #E2103700), Rheos and Rheos+, 1200, 1600, 2000, 2400 Teledyne Laars V2017600 Gas Valve, Direct Ignition, Combination, Dual Automatic Teledyne Laars RE2317300 Temperature Control with display, FX05
Honeywell L4008A1544 High Limit Switch, Auto, 135F 120" Capillary Honeywell L4008E1313 Manual Reset High-Limit Switch 210F Max LAARS 2400-286 Ignitor, Hot Surface, w/Gasket
Honeywell L4008A1544 High Limit Switch, Auto, 135F 120" Capillary Honeywell L4008E1313 Manual Reset High-Limit Switch 210F Max Laars 10-330 Ignitor, Hot Surface, w/Gasket
Laars P4T02000 Kit, Tile  Pennant 2000 Teledyne Laars E2313900 Automatic Electronic Ignition Control, 3 Tries, Natural Gas LAARS E2107300 Automatic Electronic Ignition Control, Single Try, Propane Gas or CSD-1
Laars P4T02000 Kit, Tile  Pennant 2000 Teledyne Laars E2313900 Automatic Electronic Ignition Control, 3 Tries, Natural Gas LAARS E2107300 Automatic Electronic Ignition Control, Single Try, Propane Gas or CSD-1
Teledyne Laars E2103100 Sensor Probe Teledyne Laars A2111900 Pennant Blower, Previous Part #A2108900 LAARS V2016000 Combination Gas Valve
Teledyne Laars E2103100 Sensor Probe

Teledyne Laars A2111900 Pennant Blower, Previous Part #A2108900

LAARS V2016000 Combination Gas Valve
Teledyne Laars E2103700 HTS Temperature Sensor, R2006600 LAARS 10483300 Pump Housing, Bronze LAARS 10364201 Pump Adapter, Bronze
Teledyne Laars E2103700 HTS Temperature Sensor, R2006600 LAARS 10483300 Pump Housing, Bronze LAARS 10364201 Pump Adapter, Bronze
LAARS 2400-286 Ignitor, Hot Surface, w/Gasket LAARS A2110800 Mixing System Actuator, 500-2000 LAARS A2110900 Mixing System Ball Valve, 500-2000
LAARS 2400-286 Ignitor, Hot Surface, w/Gasket LAARS A2110800 Mixing System Actuator, 500-2000 LAARS A2110900 Mixing System Ball Valve, 500-2000
Teledyne Laars 5C3017 Bracket Support, Pump Cover, Previous Part #20C3017 Laars 5C3015 Housing, Rain Shield, Pump, Pennant Laars 5C3016 Cover, Housing, Pump, Pennant
Teledyne Laars 5C3017 Bracket Support, Pump Cover, Previous Part #20C3017 Laars 5C3015 Housing, Rain Shield, Pump Laars 5C3016 Cover, Housing, Pump
Laars 10261501 Pump Housing, Glass Lined Cast Lined Neptronic 90-402823 Mixing System Actuator, 500-2000 Teledyne Laars R20607600 Pump housing Kit, Mighty Therm 500-1825, Pennant 500-2000
Laars 10261501 Pump Housing, Glass Lined Cast Lined Neptronic 90-402823 Mixing System Actuator, 500-2000 Teledyne Laars R20607600 Pump housing Kit, Mighty Therm 500-1825, Pennant 500-2000
Teledyne Laars R2027807 Tube Assembly, Cupronickel Tubes, 2000 Teledyne Laars 20C4000 Tube Assembly, Copper, Heat Exchanger, 2000 Teledyne Laars R2014905 Tube Assembly, Copper, Heat Exchanger, 2000
Teledyne Laars R2027807 Tube Assembly, Cupronickel Tubes, 2000 Teledyne Laars 20C4000 Tube Assembly, Copper, Heat Exchanger, 2000 Teledyne Laars R2014905 Tube Assembly, Copper, Heat Exchanger, 2000
Teledyne Laars 10-332 Ignitor Gasket, CB/HWG LAARS E2217700 Automatic Reset High-Limit Switch, 210F Max., PNCV LAARS E2217800 Manual Reset High-Limit Switch 210F Max., Pennant, Rheos, Mighty Therm, Mighty Max
Laars 10-332 Ignitor Gasket, CB/HWG

The igniter is a “glow bar” type silicon carbide unit. It is
energized whenever there is a call for heat and the red
"IGNITER" light on the boiler control is lit. After the igniter is
switched off and the boiler continues to run, the igniter functions
as a flame sensor for the boiler control.
If the ignitor fails and must be replaced, always install a new
igniter gasket with the replacement igniter.
CAUTION: Ignitor gets hot.
LAARS E2217700 Automatic Reset High-Limit Switch, 210F Max., PNCV

LAARS E2217800 Manual Reset High-Limit Switch 210F Max.

LAARS E2105500 Diagnostic Board LAARS E2105600 Indicator Light Board Panel LAARS A0079000 Temperature/Pressure Gauge
LAARS E2105500 Diagnostic Board LAARS E2105600 Indicator Light Board Panel LAARS A0079000 Temperature/Pressure Gauge