You are here: Home > Hydronic Heater Replacement Parts > Teledyne Laars Heating System Parts > Mighty Max Parts > Mighty Max HH > HH 0400M*20
Teledyne Laars Mighty Max HH 0400M*20
Click on this picture below to find your parts




Mighty Max Manual


(Acrobat Reader Required)
Sort By:
Page of 3
Teledyne Laars R0021300 Transformer, 40VA, 115/24V Kit, Rheos and Rheos+, 1200, 1600, 2000, 2400 LAARS R0061400 Pressure Relief Valve, 30 PSI LAARS S2003000 Heat Exchanger Gasket (Rear)
Teledyne Laars R0021300 Transformer, 40VA, 115/24V Kit, Rheos and Rheos+, 1200, 1600, 2000, 2400 LAARS R0061400 Pressure Relief Valve, 30 PSI LAARS S2003000 Heat Exchanger Gasket (Rear)
LAARS RE2000300 Fuse Holder Kit (5 pack) LAARS 20150902 Heat Exchanger Baffle 400 LAARS R20150200 Machined Bronze Inlet/Outlet Header Cover for Std. Heat Exchanger
LAARS RE2000300 Fuse Holder Kit (5 pack) LAARS 20150902 Heat Exchanger Baffle 400 LAARS R20150200 Machined Bronze Inlet/Outlet Header Cover for Std. Heat Exchanger
LAARS R20150100 Machined Bronze Rear Header Cover LAARS RS2003000 Gasket Replacement Kit LAARS Q0068400 Pilot Gas Tubing (per ft.)
LAARS R20150100 Machined Bronze Rear Header Cover LAARS RS2003000 Gasket Replacement Kit LAARS Q0068400 Pilot Gas Tubing (per ft.)
Teledyne Laars RE0240900 Pressure Switch S.P./D.T. LAARS E0015900 High Limit, Manual Reset, PNCH TELEDYNE LAARS 20150302 Adapter Tee, Flange, 2" NPT (bronze, outlet side), 500-850
Teledyne Laars RE0240900 Pressure Switch S.P./D.T. LAARS E0015900 High Limit, Manual Reset, PNCH TELEDYNE LAARS 20150302 Adapter Tee, Flange, 2" NPT (bronze, outlet side), 500-850
LAARS A2088100 Blower, Left hand, Lo Nox Mighty Therm Teledyne Laars Burner Plenum Gasket Kit, 400
LAARS A2088100 Blower, Left hand, Lo Nox Mighty Therm Teledyne Laars Burner Plenum Gasket Kit, 400 TELEDYNE LAARS R2006600 Sensor, Temperature, Johnson Control, (previous part #E2103700), Rheos and Rheos+, 1200, 1600, 2000, 2400
TELEDYNE LAARS R2007700 On/Off Switch LAARS P0076100 Compression Nut & Sleeve for Q0068400 Pilot 1/4" Gas Tubing
TELEDYNE LAARS R2007700 On/Off Switch LAARS P0076100 Compression Nut & Sleeve for Q0068400 Pilot 1/4" Gas Tubing Teledyne Laars F0011400 Header Bolt Washer
Honeywell L4008E1271 High Limit, Manual Reset, PNCH LAARS S2003100 Heat Exchanger Gasket (Front) Teledyne Laars R2023000 3-Try Ignition Control (Natural Gas) previous part #s E2101300, E2321600, E2105100
Honeywell L4008E1271 High Limit, Manual Reset, PNCH LAARS S2003100 Heat Exchanger Gasket (Front) Teledyne Laars R2023000 3-Try Ignition Control (Natural Gas) previous part #s E2101300, E2321600, E2105100
Teledyne Laars RE2101600 Digital Temperature Display LAARS RW2002300 Hot Surface Ignitor w/Gasket LAARS RE2101400 Electronic Temperature Control

Teledyne Laars RE2101600 Digital Temperature Display

LAARS RW2002300 Hot Surface Ignitor w/Gasket LAARS RE2101400 Electronic Temperature Control
Teledyne Laars E2103100 Sensor Probe Teledyne Laars E2103700 HTS Temperature Sensor, R2006600 LAARS RV2003900 Operating Gas Valve Kit 320-400
Teledyne Laars E2103100 Sensor Probe Teledyne Laars E2103700 HTS Temperature Sensor, R2006600 LAARS RV2003900 Operating Gas Valve Kit 320-400
Teledyne Laars W0038001 Ignitor & Gasket kit, Mighty Therm LoNox LAARS 20259602 Complete 4-Pass Heat Exchanger w/Copper Tubes 400 LAARS R20256102 Tube Assembly w/Copper Tubes 400
Teledyne Laars W0038001 Ignitor & Gasket kit, Mighty Therm LoNox LAARS 20259602 Complete 4-Pass Heat Exchanger w/Copper Tubes 400 LAARS R20256102 Tube Assembly w/Copper Tubes 400
Teledyne Laars RE0015900 High Limit Kit, E0015900 Teledyne Laars 10-332 Ignitor Gasket, CB/HWG LAARS A0079000 Temperature/Pressure Gauge
Teledyne Laars RE0015900 High Limit Kit, E0015900 Laars 10-332 Ignitor Gasket, CB/HWG

The igniter is a “glow bar” type silicon carbide unit. It is
energized whenever there is a call for heat and the red
"IGNITER" light on the boiler control is lit. After the igniter is
switched off and the boiler continues to run, the igniter functions
as a flame sensor for the boiler control.
If the ignitor fails and must be replaced, always install a new
igniter gasket with the replacement igniter.
CAUTION: Ignitor gets hot.
LAARS A0079000 Temperature/Pressure Gauge
Teledyne Laars RE0013000 Flow Switch, Previous Part #s:  E0013000, E0013100, RE0013100 LAARS RE2075100 Low-Water Fuel Cutoff Switch w/Manual Reset LAARS RE2077700 Pump Time Delay Relay Kit, Previous Part #E2077700
Teledyne Laars RE0013000 Flow Switch, Previous Part #s:  E0013000, E0013100, RE0013100 TELEDYNE LAARS RE2075100 Low Water Cut Off, Manual Reset, Rheos and Rheos+, 1200, 1600, 2000, 2400 TELEDYNE LAARS RE2077700 EM2 Relay Kit
LAARS E2103400 Electronic Temperature Reset Module LAARS R20150201 Machined Bronze Inlet/Outlet Header Cover for Heat Exchanger LAARS R20255400 Machined Bronze Flange 1.5"
LAARS E2103400 Electronic Temperature Reset Module LAARS R20150201 Machined Bronze Inlet/Outlet Header Cover for Heat Exchanger LAARS R20255400 Machined Bronze Flange 1.5"
LAARS R20255401 Machined Bronze Flange 2" LAARS R10391304 Machined Bronze Flange 2.5" LAARS E2058300 Nickel-Plated Immersion Well
LAARS R20255401 Machined Bronze Flange 2" LAARS R10391304 Machined Bronze Flange 2.5" LAARS E2058300 Nickel-Plated Immersion Well
LAARS E2074000 Immersion Well (Johnson Control) Kit LAARS 20266409 Round Venturi Assembly, Natural, 400 LAARS 20158602 Square Venturi Assembly, LP, 400
LAARS E2074000 Immersion Well (Johnson Control) Kit LAARS 20266409 Round Venturi Assembly, Natural, 400 LAARS 20158602 Square Venturi Assembly, LP, 400