You are here: Home > Hydronic Heater Replacement Parts > Teledyne Laars Heating System Parts > Mighty Therm Parts > Mighty Therm PH > PH 0400
Teledyne Laars Mighty Therm PH 0400
Click on this picture below to find your parts


Clickable Parts Diagram


PH Manual


(Acrobat Reader Required)
Sort By:
Page of 3
LAARS 10554800 EM2 Pump Control LAARS 10697802 Spill Switch Harness Teledyne Laars A0095700 1/6 h.p. Bronze Pump
LAARS 10554800 EM2 Pump Control LAARS 10697802 Spill Switch Harness Teledyne Laars A0095700 1/6 h.p. Bronze Pump
Teledyne Laars R0021300 Transformer, 40VA, 115/24V Kit, Rheos and Rheos+, 1200, 1600, 2000, 2400 LAARS R0061400 Pressure Relief Valve, 30 PSI TELEDYNE LAARS R0385200 Valve, LP, Standing Pilot, 1/2x3/4, all
Teledyne Laars R0021300 Transformer, 40VA, 115/24V Kit, Rheos and Rheos+, 1200, 1600, 2000, 2400 LAARS R0061400 Pressure Relief Valve, 30 PSI TELEDYNE LAARS R0385200 Valve, LP, Standing Pilot, 1/2x3/4, all
LAARS V0072700 Valve, Natural, Sys 12, 2-Stage (3/4x3/4) LAARS V0073200 Valve, LP, Sys 12, 2-Stage, 325-400 Teledyne Laars W0030600 Pilot Burner
LAARS V0072700 Valve, Natural, Sys 12, 2-Stage (3/4x3/4) LAARS V0073200 Valve, LP, Sys 12, 2-Stage, 325-400 Teledyne Laars W0030600 Pilot Burner
LAARS 10732000 Pilot Assembly, Spark Ignition, LP LAARS RE2000300 Fuse Holder Kit (5 pack) LAARS Q0068400 Pilot Gas Tubing (per ft.)
LAARS 10732000 Pilot Assembly, Spark Ignition, LP LAARS RE2000300 Fuse Holder Kit (5 pack) LAARS Q0068400 Pilot Gas Tubing (per ft.)
LAARS L0032600 Gas Orifice, Natural, 5001-8000 ft 50-125 & 2001-5000 ft 160-225, JVS, JVT LAARS L0032700 Gas Orifice, LP, 8001-10,000 ft, 50-225,JVS, JVT LAARS L0032800 Gas Orifice, LP, 5001-8000 ft 50-225, JVS, JVT
LAARS L0032600 Gas Orifice, Natural, 5001-8000 ft 50-125 & 2001-5000 ft 160-225, JVS, JVT LAARS L0032700 Gas Orifice, LP, 8001-10,000 ft, 50-225,JVS, JVT LAARS L0032800 Gas Orifice, LP, 5001-8000 ft 50-225, JVS, JVT
LAARS L0050300 Gas Orifice, Natural, 8001-10,000 ft, 50-125 & 5001-8000 ft, 160-225, JVS, JVT Teledyne Laars 10457000 Heat Exchanger Support Clip LAARS 10457500 Main Burner w/Pilot Bracket
LAARS L0050300 Gas Orifice, Natural, 8001-10,000 ft, 50-125 & 5001-8000 ft, 160-225, JVS, JVT Teledyne Laars 10457000 Heat Exchanger Support Clip LAARS 10457500 Main Burner w/Pilot Bracket
LAARS 10480205 Burner Tray, Shelf Only, 400 Teledyne Laars 10535305 Draft Hood Vent Cap Adapter Plate, 400 LAARS 10571605 Burner Tray, On/Off Standing Pilot, Natural, 400
LAARS 10480205 Burner Tray, Shelf Only, 400 Teledyne Laars 10535305 Draft Hood Vent Cap Adapter Plate, 400 LAARS 10571605 Burner Tray, On/Off Standing Pilot, Natural, 400
LAARS 10571705 Burner Tray, On/Off, Standing Pilot, LP, 400 LAARS 10571805 Burner Tray, On/Off, IID, Natural, 400 Teledyne Laars 10576101 Pilot Assembly, Standard Pilot, Natural, w/Burner
LAARS 10571705 Burner Tray, On/Off, Standing Pilot, LP, 400 LAARS 10571805 Burner Tray, On/Off, IID, Natural, 400 Teledyne Laars 10576101 Pilot Assembly, Standard Pilot, Natural, w/Burner
LAARS 10576102 Pilot Assembly, Standard Pilot, LP, w/Burner LAARS 10581805 Burner Tray Assembly, Sys 12 Natural, 2-Stage, 400 LAARS 10737305 Burner Tray, Sys 12, LP, 2-Stage, 400
LAARS 10576102 Pilot Assembly, Standard Pilot, LP, w/Burner LAARS 10581805 Burner Tray Assembly, Sys 12 Natural, 2-Stage, 400 LAARS 10737305 Burner Tray, Sys 12, LP, 2-Stage, 400
Teledyne Laars S0079100 In/Outlet Header, Cast Iron, 2-pass LAARS S0079200 Return Header, Cast Iron, 2-pass LAARS E0015900 High Limit, Manual Reset, PNCH
Teledyne Laars S0079100 In/Outlet Header, Cast Iron, 2-pass LAARS S0079200 Return Header, Cast Iron, 2-pass LAARS E0015900 High Limit, Manual Reset, PNCH
TELEDYNE LAARS R2007700 On/Off Switch LAARS P0076100 Compression Nut & Sleeve for Q0068400 Pilot 1/4" Gas Tubing
Teledyne Laars 10449505 Pool Heater High Volt Ignition Lead Assembly, R0012100 TELEDYNE LAARS R2007700 On/Off Switch LAARS P0076100 Compression Nut & Sleeve for Q0068400 Pilot 1/4" Gas Tubing
TELEDYNE LAARS V0073700 Valve, LP, Standing Pilot, 1/2x3/4, all Honeywell VR8300A3203 Valve, LP, Standing Pilot, 1/2x3/4, all TELEDYNE LAARS V0073500 Valve, 3/4x3/4, Natural, IID, all
TELEDYNE LAARS V0073700 Valve, LP, Standing Pilot, 1/2x3/4, all Honeywell VR8300A3203 Valve, LP, Standing Pilot, 1/2x3/4, all TELEDYNE LAARS V0073500 Valve, 3/4x3/4, Natural, IID, all
Honeywell VR8304H4255 Valve, 3/4" x 3/4", Natural, IID, all Teledyne Laars E0111500 Ignition Control, LP Teledyne Laars RV0073700 Valve, LP, Standing Pilot, 1/2x3/4, all, Previous Part #V0073700
Honeywell VR8304H4255 Valve, 3/4" x 3/4", Natural, IID, all Teledyne Laars E0111500 Ignition Control, LP Teledyne Laars RV0073700 Valve, LP, Standing Pilot, 1/2x3/4, all, Previous Part #V0073700
Teledyne Laars E0147000 Switch, Hi-Limit, Auto Reset Teledyne Laars S0076400 Flange, Cast Iron, Previous Part #10573600 Teledyne Laars R0360500 Blower, Mighty Therm, LoNox
Teledyne Laars E0147000 Switch, Hi-Limit, Auto Reset Teledyne Laars S0076400 Flange, Cast Iron, Previous Part #10573600 Teledyne Laars R0360500 Blower
Teledyne Laars R0360700 Air Pressure Switch, with tubing, Mighty Therm, LoNox Teledyne Laars R0360900 Flame Sensor, Mighty Therm, LoNox Teledyne Laars 10564900 EM2 Pump Control
Teledyne Laars R0360700 Air Pressure Switch, with tubing Teledyne Laars R0360900 Flame Sensor Teledyne Laars 10564900 EM2 Pump Control