Fenwal 05-384241-555 Ignition Control Board, 3 Second Pre-Purge, 10 Second Ignition

Fenwal 05-384241-555 Ignition Control Board

Fenwal Controls Inc.
0 Reviews
$0.00
  • Special Instructions:: 5-27-11 cr
Product Code: 05-384241-555
Fenwal 05-384241-555 Ignition Control Board, 3 Second Pre-Purge, 10 Second Ignition

120 VAC DIRECT SPARK IGNITION SYSTEM

This 120 VAC direct spark ignition system provides an efficient and reliable way of igniting your gas burner application. Its wide selection of features makes it the most versatile system available.

VERSATILE TO MEET YOUR SPECIFIC NEEDS
Depending on the model selected. flame sensing is achieved through the Ignition electrode or a separate local or remote flame sensing electrode. The system is available in single or multiple trial-for-ignition versions. Also selectable are a 15- or 30-second prepurge period and the length of the trial-for-ignition period. And the system module may be ordered with or without its fire retardant plastic case.

AGENCY CERTIFIED
The 05-38 system is certified by the American Gas Association as conforming to ANSI 221.20.11 is a]so certified by the Canadian Gas Association and is a UL recognized component.

COMPACT SIZE - EASY TO MOUNT
The eleetronic module (including enclosure) measures only 5.69 x 3.94 x 1.87in (144.4 x 99.9 x 47.5 mm} and weighs approximately 5.1 oz (145 g). It is not position sensitive and may be mounted vertically or horizontally using standard hardware. All connections are made with standard 1/4 inch quick connects.

INNOVATIVE DESIGN FOR SAFE AND EFFICIENT OPERATION
Flame sensing is achieved through the technique of using the high voltage spark electrode as the sensor or through a separate local or remote sensing probe. All models use the principle of flame rectification to monitor the burner flame. In addition. a patented self-monitoring misty circuit provides a type of protection not found in other ignition systems

SPEC1FCATIONS

Size
With Enclosure, 5.69 x 3.94 x 1.87 in(144 4 x 99.9 x 47.5 mm) Without Enclosure: 5.50 x 3 75 x 2.00 inf139.7 x 95.3 x 50.8 mm)Weight with enclosure)
Approximately 5.1 oz (145 g)Input Voltage
120 VAC, +10%, -15%, 50/60 Hz.Input Current Drain
90 mA RMS maximum (270 mA peak) while sparking. Does not include valve powerValve Relay Contact Rating
2.5 A (Inrush 5.0 A maximum)Prepurge
None. 15 or 30 seconds depending on model Without prepurge there is less than 1 0 second delay before single try for ignition.Ambient Temperature Limits
-40 and +155 deg. F (-40 and +65 deg. C)Moisture Resistance
Each module is conformal coated to operate to 90% R.H. However, care must be taken to protect module from direct exposure to water.Tries for Ignition
Available in one- or three-try versionsTrial-for-Ignition Periods
3 3, 4.7. 6.8. 10.0 or 12.0 seconds, depending on model.Flame Failure Retry
When loss of flame occurs after the initial try for ignition, the control system provides one retry on single-try models and two retries on three-try models.Flame Curren
t 1 microamp minimumFlame Failure Response Time
Within 0.8 second Spark Rate 60 sparks per second (synchronous) Types of Gas Natural, LP, or manufacturedConnections inch quick connectSensor
Single spark and sense using high voltage spark electrode as the sensing element or remote or local sensing using a separate sensing elementEnclosure (Optional)Gray Noryl fire retardant plasticSpecifications subject to change without notice

CONTROL CONFIGURATION