Fenwal 35-63J501-005 Ignition Control Board

Fenwal 35-63J501-005 Ignition Control Board

Fenwal Controls Inc.
0 Reviews
$0.00
$148.33
You save $0.00!
Product Code: 35-63J501-005
Fenwal 35-63J501-005 24VAC Intermittent Pilot Johnson Replacement - CSA Ignition Control Board

Used with Blodgett Pizza Oven
24 VAC Microprocessor Based Intermittent Pilot Ignition Control Johnson Controls G77x Series Replacement

FEATURES

  • Drop-in replacement for JCI G77x series
  • Safe Start and full-time flame sensing
  • Custom prepurge and interpurge timings
  • Multiple trials for ignition
  • Diagnostic LED using Fenwal fault codes
  • Three ground terminals for ease of wiring
  • Remote or local flame sense options
  • Automatic 5 min or 1 hour reset after lockout options

DESCRIPTION

The Fenwal 35-63J Series provides all the features, perfor- mance and reliability of our 35-63 Series 24 VAC intermittent pilot (spark-to-pilot) ignition control in a Johnson Controls format.

Designed to directly replace the Johnson G77x Series, the Fenwal 35-63J matches the footprint, mounting hole pattern, and wiring connections of the discontinued Johnson series.

APPLICATIONS

Directly replaces Johnson Controls G77x in:

  • Commercial cooking equipment
  • Commercial gas furnaces
  • Unit heaters
  • Water heaters

Consider the Fenwal 35-63J for IP ignition applications where a smaller footprint is desirable

ADVANTAGES

  • Microprocessor control for precise, repeatable timings and operating sequences
  • Fenwal Platform Design for easy customization of ignition cycle and timings to appliance requirements
  • High Spark Energy for fast, dependable burner ignition
  • Superior 120V Flame Sense Signal provides safe, reliable burner operation (vs. 24V design)
  • On-board diagnostics with LED display for efficient operation and easy troubleshooting

SPECIFICATIONS

Input PowerControl: 18-30 VAC 50/60 Hz (Class 2 Transformer)
Input Current Drain300 mA @24 VAC with gas and pilot relays energized (Control only)
Main Gas Valve2.0A max (continuous)
Pilot Gas Valve2.0A max (continuous)
Operating Temperature-40F to +176F (-40C to +80C)
Storage Temperature-40F to +185F (-40C to +85C)
Flame Sensitivity0.3 A minimum
Flame Failure Response or Re-ignition Time0.8 seconds maximum
Flame Detector Self-check RateOnce per second minimum
Types of GasNatural, LP, or manufactured
Spark RateRemote sense (50/60 Hz) Local sense (25/30 Hz)
Size (LxWXH)4.92 x 3.32 x 2.71 inches (with cover) 12.50 x 8.43 x 6.88 cm (with cover)
Weight8 ounces (nominal) 224 grams (nominal)
Moisture ResistanceConformal coated to operate to 95% R.H. (non-condensing)
Tries for IgnitionOne or three try versions available
Trial for Ignition Periods8, 25, 50, 85, 120 seconds available
Prepurge TimingsNone, 4, 15, or 30 seconds available
Interpurge TimingsNone, 15, 30, or 45 seconds available

CONTROL CONFIGURATION

Options

Re-ignition After Flame Loss

Enclosure

Noryl Gray Enclosure

Tries for Ignition, Flame Sense and Lockout Reset Methods

Single Try, Remote Sense Thermostat / power off reset

Pre-Purge

None

Inter-Purge

None (Single Try Only)

Trial for Ignition

50 Seconds