You are here: Home > Hydronic Heater Replacement Parts > Teledyne Laars Heating System Parts > Mighty Max Parts > Mighty Max HH > HH 1000M*20
Teledyne Laars Mighty Max HH 1000M*20
Click on this picture below to find your parts




Mighty Max Manual


(Acrobat Reader Required)
Sort By:
Page of 3
Teledyne Laars R0021300 Transformer, 40VA, 115/24V Kit, Rheos and Rheos+, 1200, 1600, 2000, 2400 LAARS RE2000300 Fuse Holder Kit (5 pack) LAARS 20150906 Heat Exchanger Baffle 1000
Teledyne Laars R0021300 Transformer, 40VA, 115/24V Kit, Rheos and Rheos+, 1200, 1600, 2000, 2400 LAARS RE2000300 Fuse Holder Kit (5 pack) LAARS 20150906 Heat Exchanger Baffle 1000
LAARS R20150200 Machined Bronze Inlet/Outlet Header Cover for Std. Heat Exchanger LAARS R20150100 Machined Bronze Rear Header Cover LAARS RS2003000 Gasket Replacement Kit
LAARS R20150200 Machined Bronze Inlet/Outlet Header Cover for Std. Heat Exchanger LAARS R20150100 Machined Bronze Rear Header Cover LAARS RS2003000 Gasket Replacement Kit
LAARS RV2003600 Gas Pressure Regulator Kit 775-1000 LAARS Q0068400 Pilot Gas Tubing (per ft.) Teledyne Laars RE0240900 Pressure Switch S.P./D.T.
LAARS RV2003600 Gas Pressure Regulator Kit 775-1000 LAARS Q0068400 Pilot Gas Tubing (per ft.) Teledyne Laars RE0240900 Pressure Switch S.P./D.T.
Teledyne Laars E0234900 Ignition Control Kit, Lo Nox Mighty Therm Teledyne Laars HH 0999M*20 HH 1000M*20 PH 0999M*20 PH 1000M*20 PW 0999M*20 PW 1000M*20 VW 0775M*20 VW 0999M*20 Flue Collector Assembly, 1000 Teledyne Laars HH 0999M*20 HH 1000M*20 PH 0999M*20 PH 1000M*20 PW 0999M*20 PW 1000M*20 VW 0775M*20 VW 0999M*20 Front/Rear Flue Collector Gasket, 1000
Teledyne Laars E0234900 Ignition Control Kit, Lo Nox Mighty Therm Teledyne Laars Flue Collector Assembly, 1000 Teledyne Laars Front/Rear Flue Collector Gasket, 1000
Teledyne Laars HH 0999M*20 HH 1000M*20 PH 0999M*20 PH 1000M*20 PW 0999M*20 PW 1000M*20 VW 0775M*20 VW 0999M*20 Burner Plenum Gasket Kit, 1000 Teledyne Laars Mini-Combo MCH <span style='color: red; font-weight:bold'> R2006600 </span>  <span style='color: green; font-weight:bold'> Sensor, Temperature, Johnson Control, (previous part #E2103700), Rheos and Rheos+, 1200, 1600, 2000, 2400 </span> TELEDYNE LAARS R2007700 On/Off Switch
Teledyne Laars Burner Plenum Gasket Kit, 1000 TELEDYNE LAARS R2006600 Sensor, Temperature, Johnson Control, (previous part #E2103700), Rheos and Rheos+, 1200, 1600, 2000, 2400 TELEDYNE LAARS R2007700 On/Off Switch
LAARS P0076100 Compression Nut & Sleeve for Q0068400 Pilot 1/4" Gas Tubing Teledyne Laars MT2H 0500 MT2H 0750 MT2H 1000 MT2H 1250 MT2H 1500 MT2H 1750 MT2H 2000 MT2V 0500 MT2V 0750 MT2V 1000 <span style='color: red; font-weight:bold'> F0011400 </span>  <span style='color: green; font-weight:bold'> Header Bolt Washer </span> Teledyne Laars V0051000 Valve, Adjustable Bleed
LAARS P0076100 Compression Nut & Sleeve for Q0068400 Pilot 1/4" Gas Tubing Teledyne Laars F0011400 Header Bolt Washer Teledyne Laars V0051000 Valve, Adjustable Bleed
Honeywell L4008E1313 Manual Reset High-Limit Switch 210F Max Honeywell L4008E1271 High Limit, Manual Reset, PNCH LAARS S2003100 Heat Exchanger Gasket (Front)
Honeywell L4008E1313 Manual Reset High-Limit Switch 210F Max Honeywell L4008E1271 High Limit, Manual Reset, PNCH LAARS S2003100 Heat Exchanger Gasket (Front)
LAARS E2107300 Automatic Electronic Ignition Control, Single Try, Propane Gas or CSD-1 LAARS E2105100 Three-Try Ignition Control (Propane Gas) Teledyne Laars R2023000 3-Try Ignition Control (Natural Gas) previous part #s E2101300, E2321600, E2105100
LAARS E2107300 Automatic Electronic Ignition Control, Single Try, Propane Gas or CSD-1 LAARS E2105100 Three-Try Ignition Control (Propane Gas) Teledyne Laars R2023000 3-Try Ignition Control (Natural Gas) previous part #s E2101300, E2321600, E2105100
Teledyne Laars RE2101600 Digital Temperature Display LAARS RW2002300 Hot Surface Ignitor w/Gasket LAARS RE2101400 Electronic Temperature Control

Teledyne Laars RE2101600 Digital Temperature Display

LAARS RW2002300 Hot Surface Ignitor w/Gasket LAARS RE2101400 Electronic Temperature Control
Teledyne Laars E2103100 Sensor Probe Teledyne Laars E2103700 HTS Temperature Sensor, R2006600 LAARS RV0046700 Automatic Safety Gas Valve Kit 775-1000
Teledyne Laars E2103100 Sensor Probe Teledyne Laars E2103700 HTS Temperature Sensor, R2006600 LAARS RV0046700 Automatic Safety Gas Valve Kit 775-1000
Teledyne Laars W0038001 Ignitor & Gasket kit, Mighty Therm LoNox Teledyne Laars HH 0999M*20 HH 1000M*20 PH 0999M*20 PH 1000M*20 PW 0999M*20 PW 1000M*20 <span style='color: red; font-weight:bold'> A2003900 </span>  <span style='color: green; font-weight:bold'> Combustion Blower Motor, Natural and LP, 775-1000 </span> LAARS 20256006 Complete 2-Pass Heat Exchanger w/Copper Tubes 1000
Teledyne Laars W0038001 Ignitor & Gasket kit, Mighty Therm LoNox Teledyne Laars A2003900 Combustion Blower Motor, Natural and LP, 775-1000 LAARS 20256006 Complete 2-Pass Heat Exchanger w/Copper Tubes 1000
LAARS R20256106 Tube Assembly w/Copper Tubes 1000 Teledyne Laars RE0015900 High Limit Kit, E0015900 Teledyne Laars 10-332 Ignitor Gasket, CB/HWG
LAARS R20256106 Tube Assembly w/Copper Tubes 1000 Teledyne Laars RE0015900 High Limit Kit, E0015900 Laars 10-332 Ignitor Gasket, CB/HWG

The igniter is a “glow bar” type silicon carbide unit. It is
energized whenever there is a call for heat and the red
"IGNITER" light on the boiler control is lit. After the igniter is
switched off and the boiler continues to run, the igniter functions
as a flame sensor for the boiler control.
If the ignitor fails and must be replaced, always install a new
igniter gasket with the replacement igniter.
CAUTION: Ignitor gets hot.
LAARS E2217800 Manual Reset High-Limit Switch 210F Max., Pennant, Rheos, Mighty Therm, Mighty Max LAARS RE2075100 Low-Water Fuel Cutoff Switch w/Manual Reset LAARS RE2077700 Pump Time Delay Relay Kit, Previous Part #E2077700

LAARS E2217800 Manual Reset High-Limit Switch 210F Max.

TELEDYNE LAARS RE2075100 Low Water Cut Off, Manual Reset, Rheos and Rheos+, 1200, 1600, 2000, 2400 TELEDYNE LAARS RE2077700 EM2 Relay Kit
LAARS E2103400 Electronic Temperature Reset Module LAARS R20150201 Machined Bronze Inlet/Outlet Header Cover for Heat Exchanger LAARS R20255401 Machined Bronze Flange 2"
LAARS E2103400 Electronic Temperature Reset Module LAARS R20150201 Machined Bronze Inlet/Outlet Header Cover for Heat Exchanger LAARS R20255401 Machined Bronze Flange 2"
LAARS R10391304 Machined Bronze Flange 2.5" LAARS 20266401 Round Venturi Assembly, Natural, 1000 LAARS 20266402 Round Venturi Assembly, LP, 1000
LAARS R10391304 Machined Bronze Flange 2.5" LAARS 20266401 Round Venturi Assembly, Natural, 1000 LAARS 20266402 Round Venturi Assembly, LP, 1000