Get Your Parts Fast! Place your order before 4PM EST and it will ship on the same or next business day.
This hot surface ignition system provides an efficient way of igniting your gas burner application. Its wide selection of features makes it the most versatile system available.
VERSATILE TO MEET YOUR SPECIFIC NEEDS
Depending on the model selected, the ignitor may operate on 120, 208/240, or 277 VAC. Combinations of these voltages are also available, allowing use with whatever standard voltage you find at the job site. The system is available in single or multiple trial-for-ignition versions. Also selectable are nominal heat up periods of 20 or 45 seconds, quick connect or AMP MATE-N-LOK connectors, a 15 second prepurge period, a 45 second postpurge period, and inducer blower control.
AGENCY CERTIFIED
The 05-33 is an interrupted-type ignition system and conforms to ANSI 221.20. This system is certified by the American Gas Association for use with natural or propane gas. It is also certified by the Canadian Gas Association and is a U.L. recognized component.
EFFICIENT OPERATION
Flame sensing is achieved through the patented technique of using the hot surface element as the sensor. However, if required, a separate sensing probe can be supplied, All models utilize the principle of flame rectification to monitor the burner flame. In addition, a self diagnostic circuit checks the valve control and the flame rectification circuit before the ignition sequence is initiated.
COMPACT SIZE - EASY TO MOUNT
The electronic package measures only 3.93 x 5.68 x 1.60 in (99.8 x 144.3 x 40.6 mm) and weighs approximately 5 oz g). It is not position-sensitive and may be mounted vertically or horizontally using #8 hardware. Connections may be made easily with quick connect or AMP MATE-N-LOK connectors.
ECONOMICAL SELF-CONTAINED INDUCER BLOWER CONTROL
If you use an inducer blower, there is no need to incur the cost and inconvenience of a separate control system. The Series 05-33 system has an optional inducer relay integral with its electronic package
Size (H x W x D) | 3.93 x 5.68 x 1.60 in(99.8 x 144.3 x 40.6 mm) |
Weight | Approximately 5 oz (140 g) |
Input Voltage | ignitor: 120, 208/240, or 277 V, 50/60 Hz Thermostat: 24 V, 50/60 Hz (Operating range 20-28 VAC) |
Input Current Drain | 100 mA, does not include valve power |
Valve Rating | 24 VAC, 1.0 A maximum, inrush 2 A maximum |
ignitor Heat-Up Time | 20 seconds nominal (18-28 seconds)45 seconds nominal (30-60 seconds) |
Inducer Contact Rating | 8 A at 250 VAC (1/4 hp) |
Ambient Temperature Limits | -40 to +160 deg. F (-40 to +70 deg. C) |
System Check Circuit | Checks valve control circuit and flame rectification circuit before ignition sequence is initiated. |
Tries for Ignition | Available in one- or three-try versions. |
Trial-For-Ignition Periods (lockout time) | 1.5, 3.0, 5.0, 7.0, 10.0, or 15.0 seconds, depending on model. |
Prepurge | None or 15 seconds, depending on model. |
Postpurge | None or 45 seconds, depending on model. |
Retry for Ignition | Loss of flame will result in one retry for ignition. (Two retries on three-trial-for-ignition model.) |
CONTROL CONFIGURATION | |